Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.508
Filtrar
1.
Int Ophthalmol ; 44(1): 194, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38656707

RESUMO

PURPOSE: To evaluate the magnitude of IOL transversal shift (ITS) after phacoemulsification and to analyse the factors contributing to IOL decentration and ITS. METHODS: 94 consecutive patients who underwent cataract surgery and IOL implantation was enrolled. Each patient underwent anterior segment optical coherence tomography with CASIA 2 (Tomey, Nagoya, Japan) to assess crystalline lens decentration, thickness and diameter seven days preoperatively and at one and sixty days postoperatively. Univariate and multivariate linear regression analysis were performed to evaluate the determinants of ITS and final decentration. RESULTS: The preoperative crystalline lens diameter was associated with the ITS and with the IOL final decentration. A positive association between the final IOL decentration and the first post-surgical day decentration was found (p < 0.0001). CONCLUSION: Greater crystalline lens diameter was associated with greater decentration and with greater ITS. Day-one IOL decentration seems to be the main determinant of final IOL decentration.


Assuntos
Segmento Anterior do Olho , Facoemulsificação , Tomografia de Coerência Óptica , Humanos , Facoemulsificação/efeitos adversos , Tomografia de Coerência Óptica/métodos , Masculino , Feminino , Idoso , Segmento Anterior do Olho/diagnóstico por imagem , Lentes Intraoculares/efeitos adversos , Pessoa de Meia-Idade , Acuidade Visual , Idoso de 80 Anos ou mais , Migração do Implante de Lente Intraocular/diagnóstico , Migração do Implante de Lente Intraocular/etiologia , Implante de Lente Intraocular/efeitos adversos , Complicações Pós-Operatórias/diagnóstico , Cristalino/diagnóstico por imagem , Estudos Prospectivos
2.
BMC Ophthalmol ; 24(1): 182, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649848

RESUMO

BACKGROUND: The precision of anterior segment biometric measurements in eyes has become increasingly important in refractive surgery. The purpose of this study is to assess the repeatability of the automatic measurements provided by a new spectral-domain optical coherence tomograph (SD-OCT)/Placido topographer (MS-39, CSO) and its agreement with a swept-source OCT (SS-OCT) biometer (CASIA SS-1000, Tomey) in patients with myopia. METHODS: The right eye of 235 subjects was scanned 3 times with both devices. The evaluated parameters included central corneal radius of the steep meridian, central corneal radius of the flat meridian, mean central corneal radius, thinnest corneal thickness, central corneal thickness, anterior chamber depth, corneal volume and diameter. The intraobserver repeatability of the MS-39 measurements was calculated using intraclass correlation coefficient (ICC), within subject standard deviation, coefficient of repeatability, coefficient of variation and repeated-measures analysis of variance of the 3 repeated measurements. The agreement between the two devices was evaluated by 95% limits of agreement (LoA). RESULTS: The majority of the parameters acquired from MS-39 showed high repeatability. The repeatability of corneal diameter was slightly lower than the other measurements, although the ICC remained high. Agreement with the CASIA SS-1000 was good, indicated by the Bland-Altman plots with narrow 95% LoA values for all parameters assessed. CONCLUSIONS: The high repeatability of automatic measurements by the new device supports its clinical application in eyes with myopia, and the good agreement between the two devices indicates they could be used interchangeably for the parameters evaluated.


Assuntos
Segmento Anterior do Olho , Córnea , Topografia da Córnea , Miopia , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Masculino , Feminino , Adulto , Miopia/diagnóstico , Miopia/fisiopatologia , Topografia da Córnea/métodos , Topografia da Córnea/instrumentação , Reprodutibilidade dos Testes , Segmento Anterior do Olho/diagnóstico por imagem , Segmento Anterior do Olho/patologia , Adulto Jovem , Córnea/diagnóstico por imagem , Córnea/patologia , Pessoa de Meia-Idade , Biometria/métodos , Adolescente , Estudos Prospectivos
3.
Invest Ophthalmol Vis Sci ; 65(4): 9, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38568619

RESUMO

Purpose: Intravitreal injection of drugs is commonly used for treatment of chorioretinal ocular pathologies, such as age-related macular degeneration. Injection causes a transient increase in the intraocular volume and, consequently, of the intraocular pressure (IOP). The aim of this work is to investigate how intravitreal flow patterns generated during the post-injection eye deflation influence the transport and distribution of the injected drug. Methods: We present mathematical and computational models of fluid motion and mass transport in the vitreous chamber during the transient phase after injection, including the previously unexplored effects of globe deflation as ocular volume decreases. Results: During eye globe deflation, significant fluid velocities are generated within the vitreous chamber, which can possibly contribute to drug transport. Pressure variations within the eye globe are small compared to IOP. Conclusions: Even if significant fluid velocities are generated in the vitreous chamber after drug injection, these are found to have negligible overall effect on drug distribution.


Assuntos
Segmento Anterior do Olho , Pressão Intraocular , Injeções Intravítreas , Transporte Biológico , Modelos Teóricos
5.
Invest Ophthalmol Vis Sci ; 65(4): 20, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38587439

RESUMO

Purpose: Axenfeld-Rieger syndrome (ARS) is characterized by ocular anomalies including posterior embryotoxon, iridocorneal adhesions, corectopia/iris hypoplasia, and developmental glaucoma. Although anterior segment defects and glaucoma contribute to decreased visual acuity, the role of potential posterior segment abnormalities has not been explored. We used high-resolution retinal imaging to test the hypothesis that individuals with ARS have posterior segment pathology. Methods: Three individuals with FOXC1-ARS and 10 with PITX2-ARS completed slit-lamp and fundus photography, optical coherence tomography (OCT), OCT angiography, and adaptive optics scanning light ophthalmoscopy (AOSLO). Quantitative metrics were compared to previously published values for individuals with normal vision. Results: All individuals demonstrated typical anterior segment phenotypes. Average ganglion cell and inner plexiform layer thickness was lower in PITX2-ARS, consistent with the glaucoma history in this group. A novel phenotype of foveal hypoplasia was noted in 40% of individuals with PITX2-ARS (but none with FOXC1-ARS). Moreover, the depth and volume of the foveal pit were significantly lower in PITX2-ARS compared to normal controls, even excluding individuals with foveal hypoplasia. Analysis of known foveal hypoplasia genes failed to identify an alternative explanation. Foveal cone density was decreased in one individual with foveal hypoplasia and normal in six without foveal hypoplasia. Two individuals (one from each group) demonstrated non-foveal retinal irregularities with regions of photoreceptor anomalies on OCT and AOSLO. Conclusions: These findings implicate PITX2 in the development of the posterior segment, particularly the fovea, in humans. The identified posterior segment phenotypes may contribute to visual acuity deficits in individuals with PITX2-ARS.


Assuntos
Segmento Anterior do Olho/anormalidades , Doenças da Córnea , Anormalidades do Olho , Oftalmopatias Hereditárias , Glaucoma , Humanos , Retina , Anormalidades do Olho/diagnóstico por imagem , Anormalidades do Olho/genética , Oftalmopatias Hereditárias/diagnóstico , Oftalmopatias Hereditárias/genética , Glaucoma/diagnóstico , Glaucoma/genética
6.
Sci Rep ; 14(1): 8279, 2024 04 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594403

RESUMO

The aim of the study was to compare the anterior segment parameters after cataract surgery in pseudoexfoliation syndrome (PEX) and control eyes. We conducted a prospective comparative study of 36 eyes (PEX group), 16 eyes (PEXG group) and 46 eyes (control group) of 98 patients after phacoemulsification with intraocular lens implantation. Before surgery, 1 week, 1 month and 3 months postoperatively, anterior chamber parameters were evaluated by swept source anterior segment optical coherence tomography (AS-OCT). Anterior chamber depth (ACD), angle opening distance (AOD500/750), trabecular-iris space area (TISA500/750), trabecular-iris angle (TIA500/750) and lens vault (LV) were assessed at each study visit. Preoperatively, ACD, AOD500/750 and TISA500/750 were significantly smaller, while LV was significantly greater in PEX and PEXG eyes than in controls. 3 months postoperatively all irido-corneal parameters and ACD were significantly greater in all study groups without intergroup differences. ACD and LV significantly increased in PEX group between 1 and 3 months after surgery while being stable in control group. Relative increases in ACD, AOD500, TISA750, TIA500/750 were significantly higher in PEX and PEXG groups than in controls. Our study finds that ACD and iridocorneal parameters in AS-OCT demonstrated significantly greater relative increases 3 months after phacoemulsification in PEX and PEXG groups than in control eyes. Significantly greater deepening of anterior chamber and opening of the irido-corneal angle may be a reason for different refractive outcomes and IOP control in patients with PEX and PEXG after routine cataract surgery.


Assuntos
Catarata , Síndrome de Exfoliação , Humanos , Tomografia de Coerência Óptica/métodos , Síndrome de Exfoliação/diagnóstico por imagem , Estudos Prospectivos , Pressão Intraocular , Câmara Anterior , Segmento Anterior do Olho/diagnóstico por imagem
7.
J AAPOS ; 28(2): 103863, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38458600

RESUMO

PURPOSE: To investigate the correlation between swept-source anterior segment optical coherence tomography (AS-OCT) and ultrasound biomicroscopy (UBM) in congenital corneal opacity (CCO). METHODS: All children with unilateral or bilateral congenital corneal opacities who underwent examination under anesthesia (EUA) and anterior segment optical coherence tomography (AS-OCT) imaging from January 1, 2022, to December 31, 2022, were included. Main outcome measures were corneal and anterior segment evaluation and correlation of UBM and AS-OCT findings. RESULTS: A total of 22 eyes of 15 patients were imaged using both technologies. The age at first EUA ranged from 11 days to 4 years. Different phenotypes were classified based on the clinical examination, UBM, and AS-OCT findings. Fourteen eyes were diagnosed with Peters anomaly, congenital corneal staphyloma was observed in 4 eyes, 2 eyes had coloboma, 1 eye had peripheral sclerocornea, and 1 eye was diagnosed with congenital primary aphakia. AS-OCT and UBM findings were closely correlated in 18 of 22 eyes (82%) but AS-OCT failed to provide detailed information in 4 eyes (18%) where UBM revealed more details. CONCLUSIONS: Although AS-OCT offers valuable preliminary data for initial assessment and counseling, it may not consistently provide precise assessments in all cases. Therefore, UBM should be considered for definitive evaluation.


Assuntos
Opacidade da Córnea , Microscopia Acústica , Criança , Humanos , Recém-Nascido , Microscopia Acústica/métodos , Tomografia de Coerência Óptica/métodos , Opacidade da Córnea/diagnóstico por imagem , Segmento Anterior do Olho/diagnóstico por imagem , Córnea/diagnóstico por imagem
8.
BMC Ophthalmol ; 24(1): 107, 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38448947

RESUMO

PURPOSE: To evaluate the association of body stature with ocular biometrics and refraction in preschool children. METHODS: A cross-sectional, school-based study was conducted in Shenzhen, China. Preschool children aged 3 to 6 from 10 randomly-selected kindergartens were recruited. Ocular biometric parameters, including axial length (AL), anterior chamber depth (ACD), vitreous chamber depth (VCD), corneal radius curvature (CR), axial length to corneal radius ratio (AL-to-CR ratio) and lens thickness (LT) were measured using non-contact partial-coherence laser interferometry. Cycloplegic refractions were obtained by a desktop autorefractor. Body height and weight were measured using standard procedures. The association between body stature and ocular biometrics were analyzed with univariable and multivariable regression model. RESULTS: A total of 373 preschoolers were included. AL, ACD, VCD, CR, and AL-to-CR ratio, were positively associated with height and weight (p < 0.05), whereas LT was negatively associated with height and weight (p < 0.01). No association was observed between stature and central cornea thickness and refraction. After adjusted for age and gender in a multivariable regression model, AL had positive associations with height (p < 0.01) and weight (p < 0.01). However, refraction had no significant association with stature parameters. CONCLUSION: Taller and heavier preschoolers had eyes with longer AL, deeper vitreous chamber, and flatter cornea. The significant associations between body stature and ocular biometric parameters reveal the driving influence of body development on the growth of eyeballs in preschoolers.


Assuntos
Segmento Anterior do Olho , Estatura , Pré-Escolar , Humanos , Estudos Transversais , Biometria , China/epidemiologia
10.
Sci Rep ; 14(1): 6787, 2024 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-38514709

RESUMO

The aim of this study was to investigate the anatomical and physiological ocular parameters in adolescents with myopia and to examine the relations between refractive error (SER), ocular biometry, body size and flexibility parameters in myopic adolescents. A cross-sectional study of 184 myopic adolescents, aged 15 to 19 years was conducted. Refractive error and corneal curvature measures of the eye were evaluated using an autorefractometer under cycloplegia. Central corneal thickness was determined by contact pachymetry. The ocular axial length, anterior and vitreous chamber depth, and lens thickness were measured using A-scan biometry ultrasonography. Height and body weight were measured according to a standardized protocol. Body mass index (BMI) was subsequently calculated. Beighton scale was used to measure joint flexibility. Body stature was positively correlated with ocular axial length (r = 0.39, p < 0.001) and vitreous chamber depth (r = 0.37, p < 0.001). There was a negative correlation between height and SER (r = - 0.46; p < 0.001). Beighton score and body weight had weak positive correlations with axial length and vitreous chamber depth, and a weak negative correlation with SER. A significantly more negative SER was observed in the increased joint mobility group (p < 0.05; U = 5065.5) as compared to normal joint mobility group: mean - 4.37 ± 1.85 D (median - 4.25; IQR - 6.25 to - 3.25 D) and mean - 3.72 ± 1.66 D (median - 3.50; IQR - 4.75 to - 2.25 D) respectively. There was a strong association between height and axial length, as well as SER. Higher degree of myopia significantly correlated with greater Beighton score (increased joint mobility).


Assuntos
Miopia , Erros de Refração , Adolescente , Humanos , Estudos Transversais , Olho/diagnóstico por imagem , Biometria , Peso Corporal , Segmento Anterior do Olho , Refração Ocular , Câmara Anterior/diagnóstico por imagem , Câmara Anterior/anatomia & histologia , Comprimento Axial do Olho/diagnóstico por imagem
11.
Int Ophthalmol ; 44(1): 160, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38536560

RESUMO

PURPOSE: To compare anterior chamber angle (ACA) parameters measured by Anterior Segment Optical Coherence Tomography (ASOCT) and biometric parameters measured by Swept-Source (SS) OCT-based biometry among patients with suspected occludable angles and open angles. METHODS: An analytical, cross-sectional study was performed on subjects attending our ophthalmology outpatient department with suspected occludable angles (van Herick grades 0, 1, and 2) in group 1, and with open angles (van Herick grades 3 and 4) in group 2. Each subject underwent a complete ophthalmic examination to exclude any intraocular pathology like cataract. We recruited 128 eyes of 64 subjects, 34 in group 1 and 30 in group 2. Each eye was henceforth subjected to ASOCT (Spectralis, Heidelberg Engineering, Heidelberg) and SS-OCT-based optical biometry (IOL Master 700, Carl Zeiss Meditec AG). Anatomical parameters were recorded and compared between the two groups. RESULTS: The main outcome measures of the study included nine ASOCT parameters (central corneal thickness [CCT], lens vault, AOD750, ACA, TISA750 [nasal and temporal], and ACW) and five optical biometric parameters (CCT, ACD, WTW, LT, and axial length). We found a significant difference (p < 0.05) among all the anatomical parameters between the two groups, except CCT which was not significantly different (p = 0.297). CONCLUSIONS: ASOCT and SSOCT biometry overcome the challenges of gonioscopy and allow screening for angle closure disease in otherwise normal subjects. ASOCT may serve as an alternative to gonioscopy as it clearly separates occludable angles from open angles in a non-invasive and objective manner.


Assuntos
Glaucoma de Ângulo Fechado , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Estudos Transversais , Pressão Intraocular , Glaucoma de Ângulo Fechado/diagnóstico , Glaucoma de Ângulo Fechado/patologia , Câmara Anterior/diagnóstico por imagem , Câmara Anterior/patologia , Biometria , Gonioscopia , Segmento Anterior do Olho/diagnóstico por imagem , Segmento Anterior do Olho/patologia
12.
Int J Mol Sci ; 25(5)2024 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-38473917

RESUMO

Ocular malformations (OMs) arise from early defects during embryonic eye development. Despite the identification of over 100 genes linked to this heterogeneous group of disorders, the genetic cause remains unknown for half of the individuals following Whole-Exome Sequencing. Diagnosis procedures are further hampered by the difficulty of studying samples from clinically relevant tissue, which is one of the main obstacles in OMs. Whole-Genome Sequencing (WGS) to screen for non-coding regions and structural variants may unveil new diagnoses for OM individuals. In this study, we report a patient exhibiting a syndromic OM with a de novo 3.15 Mb inversion in the 6p25 region identified by WGS. This balanced structural variant was located 100 kb away from the FOXC1 gene, previously associated with ocular defects in the literature. We hypothesized that the inversion disrupts the topologically associating domain of FOXC1 and impairs the expression of the gene. Using a new type of samples to study transcripts, we were able to show that the patient presented monoallelic expression of FOXC1 in conjunctival cells, consistent with the abolition of the expression of the inverted allele. This report underscores the importance of investigating structural variants, even in non-coding regions, in individuals affected by ocular malformations.


Assuntos
Anormalidades do Olho , Microftalmia , Humanos , Fatores de Transcrição/genética , Microftalmia/genética , Segmento Anterior do Olho/anormalidades , Anormalidades do Olho/genética , Alelos , Fatores de Transcrição Forkhead/genética , Mutação
13.
Int Ophthalmol ; 44(1): 15, 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38321260

RESUMO

PURPOSE: This study aims to investigate the influence of anterior chamber depth (ACD) and vault on the anterior chamber angle (ACA) morphology in myopic individuals implanted with posterior chamber phakic intraocular lenses. METHODS: This retrospective case series involved 231 eyes receiving a 13.2-mm implantable collamer lens (ICL). Preoperative anterior chamber anatomy was assessed using anterior segment optical coherence tomography (AS-OCT) and optical tomography, while postoperative evaluation employed AS-OCT. ACA morphology was characterized pre- and postoperatively through trabecular iris angle (TIA750), ACA distance opening (AOD750) and trabecular iris space area (TISA750). The influence of ACD and vault was examined by categorizing the sample into ACD (shallow, average and deep) and vault (low, optimal and high) groups. RESULTS: Preoperative ACA morphology varied based on ACD, with shallower ACDs exhibiting narrower TIA750, smaller AOD750 and TISA750. ICL implantation induced greater ACA narrowing more in the deep ACD group (TIA750 = 20.1 degrees; AOD750 = 0.82 mm and TISA750 = 0.44 mm2) compared to the shallow ACD group (TIA750 = 15.2 degrees; AOD750 = 0.44 mm and TISA750 = 0.21 mm2). Postoperatively, deeper ACDs showed larger ACAs. Increasing vault magnitude led to increased ACA narrowing, with the low vault group exhibiting smaller closure (TIA750 = 14.3 degrees; AOD750 = 0.56 mm and TISA750 = 0.29 mm2) compared to the high vault group (TIA750 = 20.8 degrees; AOD750 = 0.73 mm and TISA750 = 0.36 mm2). The magnitude of ACA narrowing associated with the vault had a consistent effect across different ACD groups. CONCLUSIONS: Posterior chamber intraocular lens implantation results in ACA narrowing, the extent of which is contingent upon preoperative anterior chamber and ACA morphology, with additional influence from vault magnitude.


Assuntos
Segmento Anterior do Olho , Glaucoma de Ângulo Fechado , Humanos , Implante de Lente Intraocular , Estudos Retrospectivos , Pressão Intraocular , Glaucoma de Ângulo Fechado/cirurgia , Câmara Anterior , Tomografia de Coerência Óptica/métodos
14.
Sci Rep ; 14(1): 3881, 2024 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-38365883

RESUMO

Primary angle closure disease (PACD) is a major cause of blindness worldwide. It has a high prevalence in East Asia, especially in China, which leads to a higher incidence of blindness than open-angle glaucoma. The aim of this study was to directly observe the circumlental space (CLS) in laser peripheral iridotomized eyes with PACD and to determine whether this structure plays a role in the pathogenesis of PACD. Fifty eyes of 50 patients with PACD, who had received laser peripheral iridotomy performed with neodymium:yttrium-aluminum-garnet were recruited from glaucoma clinics from March 2021 to May 2022, including 17 primary angle closure suspect (PACS), 16 primary angle closure (PAC) and 17 primary angle closure glaucoma (PACG). They were classified into two groups based on whether the ciliary process and the crystalline lens equator were in contact using slit-lamp photograph: the attached group and the unattached group. The demographic, clinical characteristics and anterior segment parameters measured from ultrasound biomicroscopy were compared between the attached group and the unattached group. Thirty-three eyes were assigned to the attached group and 17 eyes belonged to the unattached group. In the unattached group, the mean CLS was 0.10 ± 0.07 mm. No significant differences were identified between the different diagnosis groups in age, sex, best-corrected visual acuity, intraocular pressure, white-to-white, axial length, central corneal thickness, anterior chamber depth, flat keratometry, steep keratometry or iridotomy diameter (p > 0.05). The unattached group had shorter trabecular-ciliary process distance (p = 0.021) and larger ciliary process area (p = 0.001) compared with the attached group. Small CLS and its potential effect (partial ciliary block) might be considered as one of the mechanisms of PACD.


Assuntos
Glaucoma de Ângulo Fechado , Glaucoma de Ângulo Aberto , Humanos , Segmento Anterior do Olho/patologia , Iris/cirurgia , Iris/patologia , Glaucoma de Ângulo Aberto/patologia , Glaucoma de Ângulo Fechado/patologia , Câmara Anterior/diagnóstico por imagem , Câmara Anterior/cirurgia , Câmara Anterior/patologia , Pressão Intraocular , Cegueira/patologia
15.
Am J Med Genet A ; 194(5): e63542, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38234180

RESUMO

Axenfeld-Rieger Syndrome (ARS) type 1 is a rare autosomal dominant condition characterized by anterior chamber anomalies, umbilical defects, dental hypoplasia, and craniofacial anomalies, with Meckel's diverticulum in some individuals. Here, we describe a clinically ascertained female of childbearing age with ARS for whom clinical targeted sequencing and deletion/duplication analysis followed by clinical exome and genome sequencing resulted in no pathogenic variants or variants of unknown significance in PITX2 or FOXC1. Advanced bioinformatic analysis of the genome data identified a complex, balanced rearrangement disrupting PITX2. This case is the first reported intrachromosomal rearrangement leading to ARS, illustrating that for patients with compelling clinical phenotypes but negative genomic testing, additional bioinformatic analysis are essential to identify subtle genomic abnormalities in target genes.


Assuntos
Segmento Anterior do Olho , Anormalidades do Olho , Oftalmopatias Hereditárias , 60600 , Feminino , Humanos , Segmento Anterior do Olho/anormalidades , Anormalidades do Olho/diagnóstico , Anormalidades do Olho/genética , Anormalidades do Olho/patologia , Oftalmopatias Hereditárias/diagnóstico , Oftalmopatias Hereditárias/genética , Oftalmopatias Hereditárias/patologia , Fatores de Transcrição Forkhead/genética , Proteínas de Homeodomínio/genética
20.
Prog Retin Eye Res ; 98: 101227, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37926242

RESUMO

Primary angle closure glaucoma is a visually debilitating disease that is under-detected worldwide. Many of the challenges in managing primary angle closure disease (PACD) are related to the lack of convenient and precise tools for clinic-based disease assessment and monitoring. Artificial intelligence (AI)- assisted tools to detect and assess PACD have proliferated in recent years with encouraging results. Machine learning (ML) algorithms that utilize clinical data have been developed to categorize angle closure eyes by disease mechanism. Other ML algorithms that utilize image data have demonstrated good performance in detecting angle closure. Nonetheless, deep learning (DL) algorithms trained directly on image data generally outperformed traditional ML algorithms in detecting PACD, were able to accurately differentiate between angle status (open, narrow, closed), and automated the measurement of quantitative parameters. However, more work is required to expand the capabilities of these AI algorithms and for deployment into real-world practice settings. This includes the need for real-world evaluation, establishing the use case for different algorithms, and evaluating the feasibility of deployment while considering other clinical, economic, social, and policy-related factors.


Assuntos
Inteligência Artificial , Glaucoma de Ângulo Fechado , Humanos , Segmento Anterior do Olho , Glaucoma de Ângulo Fechado/diagnóstico , Tomografia de Coerência Óptica/métodos , Algoritmos , Pressão Intraocular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...